Product Qualification EMC
EN / IEC 61000-3-2
Harmonics
Report: 09-HG-0121.10
Appendix 3.6
Tested by: Z. Markovic IH/EMC Sign.:
Voltage Source Verification Data (Run time)
EUT: EF 517 (EUT 2) Tested by: Z. Markovic
Test category: Class-A per Ed. 2.2 (2004-11) (European limits) Test Margin: 100
Test date: 11.11.09 Start time: 10:37:47 End time: 10:43:08
Test duration (min): 5 Data file name: H-000449.cts_data
Comment: Operation mode: Making coffee, hot water and steam, at 220 V~, 60 Hz
Customer: Eugster / Frismag AG
Test Result: Pass Source qualification: Normal
Highest parameter values during test:
Voltage (Vrms): 219.92 Frequency(Hz): 60.00
I_Peak (Amps): 9.097 I_RMS (Amps): 6.111
I_Fund (Amps): 6.074 Crest Factor: 9.857
Power (Watts): 1339.0 Power Factor: 0.999
Harm# Harmonics V-rms Limit V-rms % of Limit Status
2 0.335 0.440 76.22 OK
3 0.366 1.979 18.52 OK
4 0.044 0.440 10.04 OK
5 0.052 0.879 5.94 OK
6 0.015 0.440 3.36 OK
7 0.024 0.660 3.58 OK
8 0.020 0.440 4.64 OK
9 0.019 0.440 4.31 OK
10 0.027 0.440 6.07 OK
11 0.015 0.220 6.61 OK
12 0.010 0.220 4.48 OK
13 0.028 0.220 12.51 OK
14 0.012 0.220 5.32 OK
15 0.011 0.220 5.07 OK
16 0.019 0.220 8.46 OK
17 0.010 0.220 4.49 OK
18 0.018 0.220 7.97 OK
19 0.011 0.220 4.94 OK
20 0.018 0.220 8.12 OK
21 0.011 0.220 5.14 OK
22 0.012 0.220 5.38 OK
23 0.008 0.220 3.42 OK
24 0.008 0.220 3.75 OK
25 0.010 0.220 4.40 OK
26 0.010 0.220 4.42 OK
27 0.007 0.220 3.40 OK
28 0.007 0.220 3.00 OK
29 0.010 0.220 4.73 OK
30 0.006 0.220 2.62 OK
31 0.006 0.220 2.64 OK
32 0.008 0.220 3.57 OK
33 0.008 0.220 3.62 OK
34 0.005 0.220 2.24 OK
35 0.005 0.220 2.21 OK
36 0.005 0.220 2.44 OK
37 0.007 0.220 3.24 OK
38 0.004 0.220 1.73 OK
39 0.006 0.220 2.89 OK
40 0.006 0.220 2.64 OK