Product Qualification EMC
EN 55014-2 / CISPR 14-2
EN / IEC 61000-6-2
Immunity
Report: 09-HG-0121.10
Appendix 4.6
Tested by: Z. Markovic IH/EMC Sign.:
Appliance type: EF 517 (EUT 2) Sample No: TS1.0
Temperature: 23 °C Rel. humidity: 31 % Atm. pressure: 946 hPa
Operation mode: Making coffee Date: 2010-11-11
R.F. current common mode
Test setup: Basic standard EN / IEC 61000-4-6
AC power port (CDN-M3)
Test
voltage
Observation
s during
test
Perfor-
mance
criteria
Result
Frequency (MHz)
V
Actual
Complied
Did not
comply
0.15 ... 230 (80% AM, 1 kHz)
Freq. step: 1%
Dwell time: 1000 ms
10 no influence A
:
Performance criteria: A, acc. to EN 55014-2, CISPR 14-2 @ 3 V (0.15 … 230 MHz)
Performance criteria: A, acc. to EN / IEC 61000-6-2 @ 10 V (0.15 … 80 MHz)
Observations during test: None
Remark:
: Appliance complied with a margin of
Appliance did not comply