Product Qualification EMC
EN / IEC 61000-3-2
Harmonics
Report: 09-HG-0121.10
Appendix 3.1
Tested by: Z. Markovic IH/EMC Sign.:
Harmonics – Class-A per Ed. 2.2 (2004-11)(Run time)
EUT: EF 517 (EUT 2) Tested by: Z. Markovic
Test category: Class-A per Ed. 2.2 (2004-11) (European limits) Test Margin: 100
Test date: 11.11.09 Start time: 10:46:22 End time: 10:51:43
Test duration (min): 5 Data file name: H-000450.cts_data
Comment: Operation mode: Making coffee, hot water and steam, at 230 V~, 50 Hz
Customer: Eugster / Frismag AG
Test Result: Pass Source qualification: Normal
Current & voltage waveforms
-15
-10
-5
0
5
10
15
-300
-200
-100
0
100
200
300
Current (Amps)
Voltage (Volts)
Harmonics and Class A limit line
European Limits
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
Current RMS(Amps)
Harmonic #
4 8 12 16 20 24 28 32 36 40
Test result: Pass Worst harmonic was #2 with 7.81% of the limit.